Subcellular Quantitative RNA and Protein Imaging
Multiplex, quantitative, high-resolution RNA-FISH, IF, and RNA-FISH/IF
HCR™ Gold RNA-FISH, HCR™ Gold IF, and HCR™ Gold RNA-FISH/IF enable simultaneous RNA and protein relative quantitation with subcellular resolution in the anatomical context of highly autofluorescent samples
Subcellular Quantitative Signal
Subcellular signal provides analog quantitation in the form of fluorescence voxel intensities that scale approximately linearly with the number of protein or RNA target molecules per subcellular voxel
Subcellular Quantitative RNA Imaging in a Whole-Mount Chicken Embryo
Redundant 2-Channel Detection
To illustrate the quantitative nature of subcellular HCR™ RNA-FISH, we detect a target mRNA using two probe sets that trigger different amplifiers carrying spectrally distinct fluorophores.
Fluorescence voxel intensities
High Accuracy and Precision with Subcellular Resolution
The resulting scatter plot of fluorescence voxel intensities demonstrates high accuracy (linearity with zero intercept) and precision (tight scatter around the line) for subcellular voxels (2.1×2.1×2.7 µm) within a whole-mount vertebrate embryo.
Subcellular Quantitative Protein Imaging in FFPE Human Breast Tissue Sections
Redundant 2-Channel Detection
To illustrate the quantitative nature of subcellular HCR™ IF, we detect a target protein using an unmodified 1º antibody probe and two batches of 2º antibody probes that trigger different amplifiers carrying spectrally distinct fluorophores.
Fluorescence voxel intensities
High Accuracy and Precision with Subcellular Resolution
The resulting scatter plot of fluorescence voxel intensities demonstrates high accuracy (linearity with zero intercept) and precision (tight scatter around the line) for subcellular voxels (2.0×2.0×2.5 µm) within an FFPE human breast tissue section.
Subcellular Quantitative Imaging Pointers
Precision Increases with Voxel Size
Quantitative precision increases with voxel size (so long as voxels remain smaller than the expression domains under consideration). To achieve high precision with subcellular resolution we recommend averaging pixels to obtain roughly 2×2×2 µm voxels.
​
Precision Increases with Number of Binding Sites for RNA Targets
Imaging RNA targets using HCR™ Gold RNA-FISH, precision increases with number of target-binding sites due to the benefits automatic background suppression. For subcellular quantitative HCR™ Gold RNA-FISH, we recommend using 20+ binding sites per target RNA (as permitted by target length).
Signal-to-Background Increases with Amplification Time
For subcellular protein and/or RNA imaging, we recommend overnight amplification to grow long amplification polymers that enhance the signal-to-background ratio.
​
Comparison of Subcellular HCR™ Gold to qPCR
While quantitative PCR (qPCR) enables analog RNA relative quantitation in vitro without anatomical context, subcellular HCR™ Gold RNA-FISH/IF enables analog protein and/or RNA relative quantitation in situ with anatomical context.
A new era for in situ hybridization:
multiplex, quantitative, high-resolution, sensitive, versatile, robust
Experience multiplex, quantitative, high-resolution immunfluorescence: amplified, enzyme-free, FFPE, simple
Quantitative 1-step enzyme-free HCR™ Gold signal amplification for all RNA and protein targets simultaneously